• EWCL5 with 4 hour fire resistance to BS EN 1364-1
• BSRIA free vent area validation
• EW120 Fire Resistance Classification to BS EN 13501-2
• Market Leading Free Vent performance
• Powder coated RAL 9010 as standard
• Motorised motor to open/close blades for natural ventilation
• 10 Year Warranty as standard
The IGV range of inert gas vents are designed specifically for over-pressure venting associated with Inert gas high pressure Fire Suppression Systems.
The vents can also provide protection against under-pressure venting with Synthetic gases as they have the unique feature of having reversible flanges allow installers to alter the flow configuration on site and keep the units housed within the wall and avoiding protrusions from the wall.
The Vents are offered in a number of standard sizes for installation in both internal and external walls with the availability of bespoke sizes in 100mm increments. Providing market leading performance across a range of pressures which has been validated by BSRIA under laboratory conditions to recognised standards. The vents are designed remain closed below opening 70Pa to allow room integrity testing to be carried out with ease. The units are also fully open at 95Pa giving you the best possible protection for your building.
The IGV has been successfully tested at EXOVA Warrington Fire following the performance test criteria of BS EN 1364-1 and achieving 4 hours fire resistance.
The IGV also carries EW120 Fire Resistance Classification to BS EN 13501-2.
The IGV is the first Inert Gas Pressure Relief Vent in the world that has been certified to EWCL5.
Click here to find out more on EWCL5 certification.
Vent Model 0303 and upwards fits into an internal wall thickness of 125 to 205mm with external walls 200 to 220mm.
Models 0501 & 0301 external and internal wall depths are 125mm to 205mm.
Deeper walls can be accommodated with the use of our easy fit wall liner extension sleeves. For doors and thin walls the use of our C-frame Kit can be utilised.
Demand for Apreco fire suppression vents is increasing with the recognised need for over and under pressure venting associated with Inert and Synthetic Gaseous Fire Suppression Systems.
Buildings are most commonly designed to withstand internal pressures of between 250 to 500Pa, though this can vary depending on the type of construction. The use of correctly sized and functioning pressure relief vents will protect such building structures from damage.
Apreco inert gas vents are of ‘counter-weighted’ design to prevent the risks of over and under pressurisation resulting from the use of gas fire suppression systems. The Apreco range of inert gas vents have been successfully tested to EN1364-1 criteria to provide a 4-hour fire resistance rating.
Specifically developed for these applications, the range can be used alongside a wide range of gas fire suppression systems to prevent structural damage and risk to personnel.
Maximum room pressure is controlled by the vents opening to allow air to escape, then closing when discharge is complete. This maintains the dilution of the air, so preventing re-ignition.

Standard stock models shown and sized. Bespoke sizes available upon request
Model | Free Vent Area (FVA m2) | Maximum size* (W x H mm) | Aperture size (W x H mm) | Weight** (Kg) |
---|---|---|---|---|
IGV-0301 | 0.030 Internal 0.030 External | 440 x 252 | 360 x 170 | 4.0 |
IGV-0501 | 0.050 Internal 0.050 External | 640 x 252 | 560 x 170 | 6.0 |
IGV-0303 | 0.092 Internal 0.059 External | 440 x 450 | 360 x 370 | 8.5 |
IGV-0505 | 0.250 Internal 0.163 External | 640 x 650 | 560 x 570 | 17.0 |
IGV-0707 | 0.483 Internal 0.319 External | 840 x 850 | 760 x 770 | 28.0 |
IGV-1010 | 0.976 Internal 0.650 External | 1140 x 1150 | 1060 x 1070 | 50.0 |
* Cover Grille maximum dimensions are 10mm greater than the stated IGV inert gas vent maximum size.
** Weights are indicative and relate to IGV inert gas vent and Wall Liner combined.
Vent Model 0303 and upwards fits into an internal wall thickness of 125 to 205mm with external walls 200 to 220mm.
Models 0501 & 0301 external and internal wall depths are 125mm to 205mm.
Deeper walls can be accommodated with the use of our easy fit wall liner extension sleeves. For doors and thin walls the use of our C-frame Kit can be utilised.
Wall Liner
The Wall Liner is used to line the cavity produced in the substrate and with flanges that match that of the IGV Vent to produce a clean professional looking installation.
Cover Grille
The Cover Grille(s) can be fitted directly to both to the IGV Vent and Wall Liner through the provided fixing holes. This helps to protect and hide the IGV Vent while not impeding on the Free Vent Area.
Extension Sleeve
The Extension Sleeve allows the IGV Vent to be installed in walls deeper then 205mm (External 220mm). Each Sleeve increases the depth of the installation by upto a maximum of 75mm.
The Sleeve simply clips onto the back of the Wall Liner or Weather Louvre allowing for easy installation.
C-Frame Kit
The C-Frame Kit allows the IGV Vent to be installed in narrow walls less then 125mm (External 200mm). Each C-Frame Kit decreases the wall depth requirement of the installation by 110mm.
Security Grilles
The SGL & SGM range of security grilles are designed to offer a light to medium security deterrent where Apreco Fire suppression vents and pressure relief vents could become subject to such environments.
The SGL & SGM are factory fitted to the wall liner prior to dispatch using Steel Self piecing rivets to form a series of solid mechanical joints between the two items to aid security.
The SGL & SGM are designed to also ensure the same market leading FVA is achieved as the Apreco vent its coupled to.
Weather Louvre / Weather Cowl
Aprecos High Free Vent Area (FVA) Weather Louvre used on external installations offers a large 65% FVA while ensuring the IGV Vent is protected from the outside elements.(The Louvre is used on models IGV-0303 upwards).
The Weather Cowl (used on IGV-0301 and IGV-0501 ONLY) ensures the IGV Vent is protected from the outside elements while not impeding the FVA performance.s.
Internal Wall Installation
This typical installation consists of:
1 x IGV Inert Gas Vent
1 x Wall Liner
External Wall Installation
This typical installation consists of:
1 x IGV Inert Gas Vent
1 x Weather Louvre
Deep Wall Installation
This typical installation consists of:
1 x IGV Inert Gas Vent
1 x Extension Sleeve
1 x Wall Liner
Narrow Wall Installation
This typical installation consists of:
1 x IGV Inert Gas Vent
1 x C-Frame Kit
1 x Wall Liner