PRV• Market Leading Free Vent performance
• 4 hour fire resistance to BS EN 1363-1 & BS EN 1363-2
• Industry leading quality control
• Operates purely differential pressure
• 10 Year Warranty as Standard

The pressurisation of stairwells is an increasingly common method of ensuring safe means of exit from a building on fire. Pressure control must be in place to maintain minimum and maximum stairwell pressures within agreed parameters. BS EN 12101-6:2005 (replacing BS 5588-4:1998) requires pressurised fire escapes to be maintained at 50 Pa and limited to a maximum of 60 Pa. Apreco’s extensive range of standard air pressure relief vents (dampers) are characterised by ease of installation.

A variety of bespoke external solutions are also available, including weather protection using fixed low loss louvres and penthouse louvre assemblies. Bespoke designs can handle all flow/pressure requirements in pressurised stairwells built to BS EN 12101-6:2005 (replacing BS 5588- 4:1998).

The PRV Vents can also be adapted for use where there is a requirement for pressure relief venting in industrial applications.  The PRV vents have been used in applications for the Defence Industry in combination with security louvres.

stairwell

The pressurisation of stairwells is an increasingly common method of ensuring a safe means of exit from a building on fire. Pressure control must be in place to maintain minimum and maximum stairwell pressures within agreed parameters.

BS EN 12101-6:2005 (replacing BS 5588-4:1998) requires pressurised fire escapes to be maintained at 50Pa and limited to a maximum of 60Pa.

Apreco’s of standard pressure relief vents  are characterised by ease of installation. For internal siting, the blade balancing system allows vertical, horizontal and inclined mounting. A variety of bespoke external solutions are also available, including weather protection using fixed or motorised low loss louvres and penthouse assemblies.

PRV All

Standard stock models shown and sized. Bespoke sizes available upon request

Metric
Model Volumetric Flow
Rate (m3/s)
Nominal Size
(W x H mm)
Maximum size*
(W x H mm)
Aperture size
(W x H mm)
Weight**
(Kg)
PRV-F-0303 0.360 @ 30pa
0.475 @ 50pa
0.870 @ 150pa
300 x 300 440 x 450 360 x 370 10
PRV-F-0505 1.00 @ 30pa
1.325 @ 50pa
2.420 @ 150pa
500 x 500 640 x 650 560 x 570 19
PRV-F-0707 1.965 @ 30pa
2.600 @ 50pa
4.745 @ 150pa
700 x 700 840 x 850 760 x 770 29
PRV-F-1010 4.00 @ 30pa
5.300 @ 50pa
9.680 @ 150pa
1000 x 1000 1140 x 1150 1060 x 1070 48

* Cover Grille maximum dimensions are 10mm greater than the stated PRV Vent maximum size.
** Weights are indicative and relate to PRV Vent and Wall Liner combined.
Standard Internal wall depth coverage is 100 to 180mm (External 180 to 200mm) extension Sleeve(s) can be added in 75mm increments.

Imperial
Model Volumetric Flow
Rate (ft3/s)
Nominal Size
(W x H in)
Maximum size*
(W x H in)
Aperture size
(W x H in)
Weight**
(lb)
PRV-F-0303 12.71 @ 0.12in wc
16.77 @ 0.20in wc
30.72 @ 0.60in wc
11.80 x 11.80 17.30 x 17.70 14.20 x 14.60  22lb 0oz
PRV-F-0505 35.32 @ 0.12in wc
46.79 @  0.20in wc
85.46 @ 0.60in wc
19.70 x 19.70 25.20 x 25.60 22.00 x 22.40  41lb 14oz
PRV-F-0707 69.39 @ 0.12in wc
91.82 @  0.20in wc
167.57 @ 0.60in wc
27.60 x 27.60 33.10 x  33.50  29.90 x 30.30  63lb 15oz
PRV-F-1010 141.26 @ 0.12in wc
187.17 @  0.20in wc
341.85 @ 0.60in wc
39.40 x 39.40 44.90 x 45.30 41.70 x 42.10 105lb 13oz

* Cover Grille maximum dimensions are 0.39″ greater than the stated PRV Vent maximum size.
** Weights are indicative and relate to PRV Vent and Wall Liner combined.
Standard Internal wall depth coverage is 4.13 to 7.09" (External7.09 to 7.87") extension Sleeve(s) can be added in 2.9" increments.

Wall LinerBacking Flange

The Wall Liner is used to line the cavity produced in the substrate and with flanges that match that of the PRV Vent to produce a clean professional looking installation.

Icon WAL Drawing

49.06 KB Rev: 001

Cover Grille

Cover Grille The Cover Grille(s) can be fitted directly to both to the PRV Vent and Wall Liner through the provided fixing holes. This helps to protect and hide the PRV Vent while not impeding on the Free Vent Area.

Icon CVG Drawing

65.44 KB Rev: 001

Extension Sleeve

Ext SleeveThe Extension Sleeve allows the PRV Vent to be installed in walls deeper then 180mm (External 200mm). Each Sleeve increases the depth of the installation by upto a maximum of 75mm.
The Sleeve simply clips onto the back of the Wall Liner or Weather Louvre allowing for easy installation.

Icon EXT Drawing

44.97 KB Rev: 001

C-Frame Kit

C-frameThe C-Frame Kit allows the PRV Vent to be installed in narrow walls less then 100mm (External 180mm). Each C-Frame Kit decreases the wall depth requirement of the installation by 110mm.

Icon CFK Drawing

47.87 KB Rev: 001

Security Grilles

C-frameThe SGL & SGM range of security grilles are designed to offer a light to medium security deterrent where Apreco Fire suppression vents and pressure relief vents could become subject to such environments.
The SGL & SGM are factory fitted to the wall liner prior to dispatch using Steel Self piecing rivets to form a series of solid mechanical joints between the two items to aid security.
The SGL & SGM are designed to also ensure the same market leading FVA is achieved as the Apreco vent its coupled to.

Icon SGL/SGM Drawing

52.46 KB Rev: 001

Weather Louvre

Weather LouvreApreco's High Free Vent Area (FVA) Weather Louvre used on external installations offers a large 65% FVA while ensuring the PRV Vent is protected from the outside elements.

Icon FWL Drawing

42.26 KB Rev: 001

Internal Wall Installation

Internal

This typical installation consists of:
2 x Cover Grilles
1 x PRV Vent
1 x Wall Liner

External Wall Installation

External
This typical installation consists of:
1 x PRV Vent
1 x Weather Louvre

Deep Wall Installation

Deep
This typical installation consists of:
1 x PRV Vent
1 x Extension Sleeve
1 x Wall Liner

Narrow Wall Installation

Narrow
This typical installation consists of:
1 x PRV Vent
1 x C-Frame Kit
1 x Wall Liner

Information

PRV
• Market Leading Free Vent performance
• 4 hour fire resistance to BS EN 1363-1 & BS EN 1363-2
• Industry leading quality control
• Operates purely differential pressure
• 10 Year Warranty as Standard

The pressurisation of stairwells is an increasingly common method of ensuring safe means of exit from a building on fire. Pressure control must be in place to maintain minimum and maximum stairwell pressures within agreed parameters. BS EN 12101-6:2005 (replacing BS 5588-4:1998) requires pressurised fire escapes to be maintained at 50 Pa and limited to a maximum of 60 Pa. Apreco’s extensive range of standard air pressure relief vents (dampers) are characterised by ease of installation.

A variety of bespoke external solutions are also available, including weather protection using fixed low loss louvres and penthouse louvre assemblies. Bespoke designs can handle all flow/pressure requirements in pressurised stairwells built to BS EN 12101-6:2005 (replacing BS 5588- 4:1998).

The PRV Vents can also be adapted for use where there is a requirement for pressure relief venting in industrial applications.  The PRV vents have been used in applications for the Defence Industry in combination with security louvres.

”Application”
stairwell

The pressurisation of stairwells is an increasingly common method of ensuring a safe means of exit from a building on fire. Pressure control must be in place to maintain minimum and maximum stairwell pressures within agreed parameters.

BS EN 12101-6:2005 (replacing BS 5588-4:1998) requires pressurised fire escapes to be maintained at 50Pa and limited to a maximum of 60Pa.

Apreco’s of standard pressure relief vents  are characterised by ease of installation. For internal siting, the blade balancing system allows vertical, horizontal and inclined mounting. A variety of bespoke external solutions are also available, including weather protection using fixed or motorised low loss louvres and penthouse assemblies.

”Vent
PRV All

Standard stock models shown and sized. Bespoke sizes available upon request

Metric
Model Volumetric Flow
Rate (m3/s)
Nominal Size
(W x H mm)
Maximum size*
(W x H mm)
Aperture size
(W x H mm)
Weight**
(Kg)
PRV-F-0303 0.360 @ 30pa
0.475 @ 50pa
0.870 @ 150pa
300 x 300 440 x 450 360 x 370 10
PRV-F-0505 1.00 @ 30pa
1.325 @ 50pa
2.420 @ 150pa
500 x 500 640 x 650 560 x 570 19
PRV-F-0707 1.965 @ 30pa
2.600 @ 50pa
4.745 @ 150pa
700 x 700 840 x 850 760 x 770 29
PRV-F-1010 4.00 @ 30pa
5.300 @ 50pa
9.680 @ 150pa
1000 x 1000 1140 x 1150 1060 x 1070 48

* Cover Grille maximum dimensions are 10mm greater than the stated PRV Vent maximum size.
** Weights are indicative and relate to PRV Vent and Wall Liner combined.
Standard Internal wall depth coverage is 100 to 180mm (External 180 to 200mm) extension Sleeve(s) can be added in 75mm increments.

Imperial
Model Volumetric Flow
Rate (ft3/s)
Nominal Size
(W x H in)
Maximum size*
(W x H in)
Aperture size
(W x H in)
Weight**
(lb)
PRV-F-0303 12.71 @ 0.12in wc
16.77 @ 0.20in wc
30.72 @ 0.60in wc
11.80 x 11.80 17.30 x 17.70 14.20 x 14.60  22lb 0oz
PRV-F-0505 35.32 @ 0.12in wc
46.79 @  0.20in wc
85.46 @ 0.60in wc
19.70 x 19.70 25.20 x 25.60 22.00 x 22.40  41lb 14oz
PRV-F-0707 69.39 @ 0.12in wc
91.82 @  0.20in wc
167.57 @ 0.60in wc
27.60 x 27.60 33.10 x  33.50  29.90 x 30.30  63lb 15oz
PRV-F-1010 141.26 @ 0.12in wc
187.17 @  0.20in wc
341.85 @ 0.60in wc
39.40 x 39.40 44.90 x 45.30 41.70 x 42.10 105lb 13oz

* Cover Grille maximum dimensions are 0.39″ greater than the stated PRV Vent maximum size.
** Weights are indicative and relate to PRV Vent and Wall Liner combined.
Standard Internal wall depth coverage is 4.13 to 7.09″ (External7.09 to 7.87″) extension Sleeve(s) can be added in 2.9″ increments.

”Accessories”

Wall Liner

Backing Flange
The Wall Liner is used to line the cavity produced in the substrate and with flanges that match that of the PRV Vent to produce a clean professional looking installation.

Cover Grille

Cover Grille
The Cover Grille(s) can be fitted directly to both to the PRV Vent and Wall Liner through the provided fixing holes. This helps to protect and hide the PRV Vent while not impeding on the Free Vent Area.

Extension Sleeve

Ext Sleeve
The Extension Sleeve allows the PRV Vent to be installed in walls deeper then 180mm (External 200mm). Each Sleeve increases the depth of the installation by upto a maximum of 75mm.
The Sleeve simply clips onto the back of the Wall Liner or Weather Louvre allowing for easy installation.

C-Frame Kit

C-frame
The C-Frame Kit allows the PRV Vent to be installed in narrow walls less then 100mm (External 180mm). Each C-Frame Kit decreases the wall depth requirement of the installation by 110mm.

Security Grilles

C-frameThe SGL & SGM range of security grilles are designed to offer a light to medium security deterrent where Apreco Fire suppression vents and pressure relief vents could become subject to such environments.
The SGL & SGM are factory fitted to the wall liner prior to dispatch using Steel Self piecing rivets to form a series of solid mechanical joints between the two items to aid security.
The SGL & SGM are designed to also ensure the same market leading FVA is achieved as the Apreco vent its coupled to.

Icon SGL/SGM Drawing

52.46 KB Rev: 001

Weather Louvre

Weather Louvre
Apreco’s High Free Vent Area (FVA) Weather Louvre used on external installations offers a large 65% FVA while ensuring the PRV Vent is protected from the outside elements.

”Typical

Internal Wall Installation

Internal-6001

This typical installation consists of:
1 x PRV Vent
1 x Wall Liner

External Wall Installation

External-600
This typical installation consists of:
1 x PRV Vent
1 x Weather Louvre

Deep Wall Installation

Deep-600
This typical installation consists of:
1 x PRV Vent
1 x Extension Sleeve
1 x Wall Liner

Narrow Wall Installation

Narrow-6001
This typical installation consists of:
1 x PRV Vent
1 x C-Frame Kit